770.216

Therm-O-Disc Thermal fuse link E4A 10A 216°C THT axial

E4A216E4A216
Manufacturer Part No.
770.216
Schukat Part No.
E4A216
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

125 Pcs. in stock

Planned delivery time
Ø 15 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available (from stock)
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 100 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 25 or multiple of 25)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Type
Temperature fuse
Series
E4A
Rated current
10 A
Rated voltage V AC
250 V AC
Nominal temperature
216 °C
Continuous operating temperature
191 °C
Switch-off temperature, max.
375 °C
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • Therm-O-Disc
Series
  • E4A
Type
  • Temperature fuse
Product group
  • E1115
Assembly
  • axial
Fastening
  • THT
Applications
  • • For mounting or installation directly at the heat source on electrical household appliances, transformers and devices of all kinds.
    • For switching off devices when the permissible operating temperature is exceeded.
Termination Style
  • Solder connection
Connection wires-Ø
  • 1 mm
Features
  • • Rigid housing in dustproof and dirtproof design
    • Reacts to ambient temperature and is conditionally sensitive to current at rated load
    • Must be replaced after the fuse has tripped

Application note
  • • When using thermal fuses, the self-heating of the current must be taken into account.
    • Thermal fuses with forced ventilation can carry higher currents.

Dimensions and Weights

Dimension: Length
  • 63 mm
Diameter
  • 4 mm

Technical Features

Rated current
  • 10 A
Rated voltage V AC
  • 250 V AC
Nominal temperature
  • 216 °C
Continuous operating temperature
  • 191 °C
Switch-off temperature, max.
  • 375 °C

Safety/Certifications

Approvals
  • UL
  • VDE
  • cCSA
Standards
  • IEC 691 / EN 60691, VDE / DIN EN 60691