3403.0284.11

Schurter SMD fuse UMT-H inert 277VAC 250VDC 1.500A 16x5,3mm

Image similar
Manufacturer Part No.
3403.0284.11
Schukat Part No.
3403.0284.11
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

70 Pcs. in stock

Planned delivery time
Ø 12 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available (from stock)
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 100 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 10 or multiple of 10)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Type
SMD fuse
Series
UMT-H
Characteristic
inert
Package/Case
16 x 5,3 mm
Rated voltage V AC
277 V AC
Rated voltage V DC
250 V DC
Voltage drop
73 mV
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • Schurter
Series
  • UMT-H
Type
  • SMD fuse
Product group
  • E1368 Schurter Series UMT-H SMD Fuse T
Characteristic
  • inert
Contact material
  • Copper alloy silver plated
Package/Case
  • 16 x 5,3 mm
Applications
  • Primary protection on SMD circuit boards | suitable for pulsed continuous currents
Housing material
  • Ceramics
Labelling
  • Logo, rated current, voltage, characteristics, switching capacity, approvals
Material
  • Copper alloy, silver plated
Termination Style
  • SMD
Features
  • loose goods

Dimensions and weights

Dimension: Length
  • 15.4 mm
Dimension: Width
  • 5.35 mm
Dimension: Height
  • 5.35 mm
Weight
  • 1.42 g

Operating conditions

Operating temperature range, min.
  • -55 °C
Operating temperature range, max.
  • 125 °C
Climate category IEC
  • 55/125/21

Technical features

Rated current
  • 10 A
Melting integral
  • 180 A²/s
Rated breaking capacity
  • 1.500 A
Rated voltage V AC
  • 277 V AC
Rated voltage V DC
  • 250 V DC
Voltage drop
  • 73 mV
Power loss, max.
  • 1.220 mW
Solderability
  • 245 °C / 30 s

Safety/Certifications

Approvals
  • CE
  • CQC
  • IEC
  • UK CA
  • UL
  • VDE
  • cULus
Standards
  • UL 248-14, IEC 60127-7, IEC/UL 62368-1