0034.3769

Schurter Device fuse link 5x20mm FSL inert 250VAC 0,315A

Image similar
Manufacturer Part No.
0034.3769
Schukat Part No.
0034.3769
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

0 Pcs. in stock

Planned delivery time
Ø 99 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
LTB 30.03.2025
Discontinued by manufacturer without replacement
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 10 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 1000 or multiple of 1000)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Series
FSL
Characteristic
inert
Rated voltage V AC
250 V AC
Rated current
0.315 A
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • Schurter
Series
  • FSL
Type
  • Device fuse
Product group
  • E1446 Schurter FSL 5x20mm Fuse Medium Time-Lag UL
Characteristic
  • inert
Package/Case
  • 5 x 20 mm
Material Terminal
  • nickel-plated copper alloy

Dimensions and weights

Weight
  • 1 g

Operating conditions

Operating temperature range, min.
  • -40 °C
Operating temperature range, max.
  • 85 °C
Climate category IEC
  • 40/85/21

Technical features

Rated current
  • 0.315 A
Melting integral
  • 0.345 A²/s
Rated breaking capacity
  • 35 A
Rated voltage V AC
  • 250 V AC
Voltage drop
  • 250 mV
Power loss, max.
  • 79 mW

Safety/Certifications

Approvals
  • CE
  • IEC
  • UK CA
  • UL
  • cCSA
  • cULus
Standards
  • UL 248-14, CSA22.2 No. 248.14, IEC/UL 62368-1