160016.1GT

SIBA SMD fuse 160016 inert 305VAC 1A 1.500A 16,4x4,4mm

Image similar
Manufacturer Part No.
160016.1GT
Schukat Part No.
SIBA160016-1
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

1.390 Pcs. in stock

Planned delivery time
Ø 17 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available (from stock)
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 1500 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 10 or multiple of 10)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Type
SMD fuse
Series
160016
Characteristic
inert
Package/Case
16,4 x 4,4 mm
Rated voltage V AC
305 V AC
Voltage drop
380 mV
Rated current
1 A
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • SIBA
Series
  • 160016
Type
  • SMD fuse
Product group
  • E1358 SIBA SMD-Subm. Fuse-Links, 250V, 4,5x16mm, Time-Lag
Characteristic
  • inert
Contact material
  • Copper alloy silver plated
Package/Case
  • 16,4 x 4,4 mm
Material
  • Copper alloy, silver plated

Dimensions and weights

Dimension: Length
  • 16 mm
Dimension: Width
  • 4.4 mm
Dimension: Height
  • 4.4 mm

Technical features

Rated current
  • 1 A
Melting integral
  • 4.5 A²/s
Rated breaking capacity
  • 1.500 A
Rated voltage V AC
  • 305 V AC
Voltage drop
  • 380 mV
Power loss, max.
  • 640 mW
Solderability
  • 260 °C / 10 s

Safety/Certifications

Approvals
  • SEMKO
  • cULus
Standards
  • IEC 60127-4/2, UL 248-14