RPA150Q-11024SRUW/P

Recom DC/DC converter regulated 6,25 V 6,25 A 1/8 Brick 4.242 V

Manufacturer Part No.
RPA150Q-11024SRUW/P
Schukat Part No.
RPA150Q-11024SRUWP
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

0 Pcs. in stock

Planned delivery time
Ø 60 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available on order
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 1 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 1 or multiple of 1)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Operating mode
regulated
Package/Case
1/8 Brick
Output Power
150 W
Output voltage
6.25 V
Output current
6.250 A
Isolation voltage I/P-O/P
4,242 V
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • Recom
Series
  • RPA150Q-RUW
Product group
  • M2094 Recom ROA150Q-RUW DC/DC Converter 1/4 Brick 150W
Application
  • ITE
  • Industry
  • Railway
Operating mode
  • regulated
Package/Case
  • 1/8 Brick
Dimension: Length
  • 60.6 mm
Dimension: Width
  • 39 mm
Dimension: Height
  • 12.7 mm
Weight
  • 88 g
Manufacturer's warranty (years)
  • 3
Features
  • Adjustable Output Voltage
  • Remote Function
  • Remote Sense

Operating conditions

MTBF
  • 597,000 h
Operating Temperature Min.
  • -40 °C
Operating Temperature Max.
  • 85 °C
Storage Temperature Min.
  • -40 °C
Storage Temperature Max.
  • 125 °C

Input

Input voltage min. DC
  • 14.4 V
Input voltage max. DC
  • 170 V
Input voltage range
  • 6:1
Efficiency
  • 89 %
Connection type, input
  • THT

Output

Number of outputs
  • 1
Output Power
  • 150 W
Output voltage
  • 6.25 V
Output Voltage Min.
  • 5 V
Output Voltage Max.
  • 7.375 V
Output voltage tolerance
  • -1 %
Output current
  • 6.250 A
Overload protection
Type of overload protection
  • Hiccup
Short-circuit protection
Overvoltage protection
Overtemperature protection
Connection type, output
  • THT
Capacitive load, max.
  • 5,000 µF

Safety/Certifications

Isolation voltage I/P-O/P
  • 4,242 V
Approvals
  • CE
  • CSA
  • EN
  • UKCA
  • UL
Standards (safety)
  • EN 62368-1
  • UL 62368-1