RACM60-12SK/OF/PCB-T

Recom AC/DC industrial power supply unit Open Frame 60W 12,00V 5,000A

RACM60-12SK/OF/PCBRACM60-12SK/OF/PCB
Manufacturer Part No.
RACM60-12SK/OF/PCB-T
Schukat Part No.
RACM60-12SK/OF/PCB
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

0 Pcs. in stock

Planned delivery time
Ø 26 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available on order
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 12 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 1 or multiple of 1)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Notice
Cross-references:
You can find suitable surge protection devices here.
Here you will find suitable inrush current limiters.
Here you will find suitable EMC and interference suppression components.

Package/Case
Open Frame
Output Power
60 W
Output voltage
12 V
Output current
5.000 A
Efficiency
90 %
RoHS-Conform

Specifications

Close all

General

Manufacturer
  • Recom
Series
  • RACM60-K
Product group
  • M3322
Application
  • Household
  • ITE
  • Industry
  • Medical
Package/Case
  • Open Frame
Dimension: Length
  • 78.4 mm
Dimension: Width
  • 53 mm
Dimension: Height
  • 35.4 mm
Weight
  • 111 g
Manufacturer's warranty (years)
  • 3
Features
  • DC compatible
Application note
  • These power supplies are considered as a component that has to be installed in a final equipment.
Notice

Operating conditions

MTBF
  • 900,000 h
Operating Temperature Min.
  • -40 °C
Operating Temperature Max.
  • 85 °C
Storage Temperature Min.
  • -40 °C
Storage Temperature Max.
  • 90 °C

Input

Mains connection/phases
  • I
Mains frequency min.
  • 47 Hz
Mains frequency max.
  • 63 Hz
Input voltage min. AC
  • 80 V
Input voltage max. AC
  • 264 V
Input voltage min. DC
  • 120 V
Input voltage max. DC
  • 370 V
Input current
  • 0.6 A
Efficiency
  • 90 %
No load power, less than
  • 0.1 W
Inrush current, max.
  • 60 A
Connection type, input
  • THT

Output

Number of outputs
  • 1
Output Power
  • 60 W
Output voltage
  • 12 V
Output voltage tolerance
  • -2.2 %
Ripple & Noise
  • 120 mVp-p
Output current
  • 5.000 A
Overload protection
Type of overload protection
  • Hiccup
Short-circuit protection
Overvoltage protection
Overtemperature protection
Connection type, output
  • THT

Safety/Certifications

Protection class
  • II
Isolation voltage I/P-O/P
  • 4,000 V
Approvals
  • CE
  • CSA
  • EN
  • IEC
  • UKCA
Standards (EMC)
  • EN 55032
  • EN 60601-1-2
Standards (safety)
  • ANSI/AAMI ES 60601-1

Documents