Filter articles
Manufacturer
Manufacturer
Series
Series
Input voltage min. DC
Input voltage min. DC
Input voltage max. DC
Input voltage max. DC
Output Power
Output Power
Number of outputs
Number of outputs
Output voltage
Output voltage
Output current
Output current
Operating mode
Operating mode
Package/Case
Package/Case
Isolation voltage I/P-O/P
Isolation voltage I/P-O/P
Efficiency
Efficiency
Operating Temperature Min.
Operating Temperature Min.
Operating Temperature Max.
Operating Temperature Max.
Dimension: Length
Dimension: Length
Dimension: Width
Dimension: Width
Dimension: Height
Dimension: Height
Connection type, output
Connection type, output
Application
Application
Approvals
Approvals
Standards (safety)
Standards (safety)
Features
Features
Results (2077)
Not discontinued
In stock
RoHS compliant
Datasheet
New
Show Selected | Image | Part No. | Indiv. Part No. | Manufacturer | Price | Availability | Quantity | Series | Data Sheet | RoHS | Manufacturer | Input voltage min. DC | Input voltage max. DC | Output Power | Number of outputs | Output voltage | Output current | Operating mode | Package/Case | Isolation voltage I/P-O/P | Efficiency | Operating Temperature Min. | Operating Temperature Max. | Dimension: Length | Dimension: Width | Dimension: Height | Connection type, output | Application | Approvals | Standards (safety) | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1926 | Manufacturers Part No. SI06W8-12(SI06W8-12) MEAN WELL DC/DC converter regulated 12 V 0,5 A 1"*1" 3.000 V New | Customer Part No. Customer Project No. | 5 Pcs. | (at least 1 or mul. of 1) | MEAN WELL | 9.0 V | 75.0 V | 6.0 W | 1 | 12.0 V | 0.5 A | regulated | 1"*1" | 3000.0 V | 85.0 % | -40.0 °C | 90.0 °C | 25.4 mm | 25.4 mm | 10.2 mm | THT | ITE Industry | CE EAC UKCA | ||||||||
1927 | Manufacturers Part No. RQB60W12-110S54(RQB60W12-110S54) MEAN WELL DC/DC converter regulated 54 V 1,111 A 1/4 Brick 3.000 V New | Customer Part No. Customer Project No. | 5 Pcs. Planned Delivery Time Ø 16 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 14.0 V | 160.0 V | 60.0 W | 1 | 54.0 V | 1.111 A | regulated | 1/4 Brick | 3000.0 V | 91.5 % | -40.0 °C | 90.0 °C | 57.9 mm | 36.8 mm | 12.7 mm | THT | ITE Industry Railway | CE EAC IEC UKCA UL | EN 50155 EN 61343 IEC 60571 IEC 62368-1 UL 62368-1 | Adjustable Output Voltage Remote Function Remote Sense | ||||||
1928 | Manufacturers Part No. RQB60W12-110S24(RQB60W12-110S24) MEAN WELL DC/DC converter regulated 24 V 2,5 A 1/4 Brick 3.000 V New | Customer Part No. Customer Project No. | 4 Pcs. Planned Delivery Time Ø 16 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 14.0 V | 160.0 V | 60.0 W | 1 | 24.0 V | 2.5 A | regulated | 1/4 Brick | 3000.0 V | 89.0 % | -40.0 °C | 90.0 °C | 57.9 mm | 36.8 mm | 12.7 mm | THT | ITE Industry Railway | CE EAC IEC UKCA UL | EN 50155 EN 61343 IEC 60571 IEC 62368-1 UL 62368-1 | Adjustable Output Voltage Remote Function Remote Sense | ||||||
1929 | Manufacturers Part No. RQB60W12-110S05(RQB60W12-110S05) MEAN WELL DC/DC converter regulated 5 V 12 A 1/4 Brick 3.000 V New | Customer Part No. Customer Project No. | 4 Pcs. Planned Delivery Time Ø 16 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 14.0 V | 160.0 V | 60.0 W | 1 | 5.0 V | 12.0 A | regulated | 1/4 Brick | 3000.0 V | 89.0 % | -40.0 °C | 90.0 °C | 57.9 mm | 36.8 mm | 12.7 mm | THT | ITE Industry Railway | CE EAC IEC UKCA UL | EN 50155 EN 61343 IEC 60571 IEC 62368-1 UL 62368-1 | Adjustable Output Voltage Remote Function Remote Sense | ||||||
1930 | Manufacturers Part No. DI06W8-05(DI06W8-05) MEAN WELL DC/DC converter regulated -5 V -0,6 A 1"*1" 3.000 V New | Customer Part No. Customer Project No. | 10 Pcs. Planned Delivery Time Ø 22 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 9.0 V | 75.0 V | 6.0 W | 2 | -5.0 V | -0.6 A | regulated | 1"*1" | 3000.0 V | 81.0 % | -40.0 °C | 90.0 °C | 25.4 mm | 25.4 mm | 10.2 mm | THT | ITE Industry | CE EAC UKCA | ||||||||
1931 | Manufacturers Part No. DI06W8-15(DI06W8-15) MEAN WELL DC/DC converter regulated -15 V -0,2 A 1"*1" 3.000 V New | Customer Part No. Customer Project No. | 0 Pcs. | (at least 1 or mul. of 1) | MEAN WELL | 9.0 V | 75.0 V | 6.0 W | 2 | -15.0 V | -0.2 A | regulated | 1"*1" | 3000.0 V | 84.5 % | -40.0 °C | 90.0 °C | 25.4 mm | 25.4 mm | 10.2 mm | THT | ITE Industry | CE EAC UKCA | ||||||||
1932 | Manufacturers Part No. DI06W8-12(DI06W8-12) MEAN WELL DC/DC converter regulated -12 V -0,25 A 1"*1" 3.000 V New | Customer Part No. Customer Project No. | 10 Pcs. Planned Delivery Time Ø 22 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 9.0 V | 75.0 V | 6.0 W | 2 | -12.0 V | -0.25 A | regulated | 1"*1" | 3000.0 V | 85.0 % | -40.0 °C | 90.0 °C | 25.4 mm | 25.4 mm | 10.2 mm | THT | ITE Industry | CE EAC UKCA | ||||||||
1933 | Manufacturers Part No. RSO-123.3S(RSO-123.3S) Recom DC/DC converter regulated 3,30 V 0,300 A SIP8 1.000 V | Customer Part No. Customer Project No. | 69 Pcs. Planned Delivery Time Ø 17 Weeks | (at least 1 or mul. of 1) | Recom | 9.0 V | 18.0 V | 1.0 W | 1 | 3.3 V | 0.3 A | regulated | SIP8 | 1000.0 V | 80.0 % | -40.0 °C | 85.0 °C | 21.8 mm | 9.2 mm | 11.1 mm | THT | ITE Industry Medical | CSA EAC EN IEC UL | EN 60950-1 IEC 60601-1 IEC 60950-1 UL 60950-1 | Remote Function | ||||||
1934 | Manufacturers Part No. RSO-1205SZ(RSO-1205SZ) Recom DC/DC converter regulated 5,00 V 0,200 A SIP8 1.000 V | Customer Part No. Customer Project No. | 22 Pcs. Planned Delivery Time Ø 17 Weeks | (at least 1 or mul. of 1) | Recom | 4.5 V | 18.0 V | 1.0 W | 1 | 5.0 V | 0.2 A | regulated | SIP8 | 1000.0 V | 80.0 % | -40.0 °C | 75.0 °C | 21.8 mm | 9.2 mm | 11.1 mm | THT | ITE Industry Medical | CSA EAC EN IEC UL | EN 60950-1 IEC 60601-1 IEC 60950-1 UL 60950-1 | Remote Function | ||||||
1935 | Manufacturers Part No. RSO-2405SZ/H3(RSO-2405SZ/H3) Recom DC/DC converter regulated 5,00 V 0,200 A SIP8 3.000 V | Customer Part No. Customer Project No. | 16 Pcs. Planned Delivery Time Ø 6 Weeks | (at least 1 or mul. of 1) | Recom | 9.0 V | 36.0 V | 1.0 W | 1 | 5.0 V | 0.2 A | regulated | SIP8 | 3000.0 V | 78.0 % | -40.0 °C | 75.0 °C | 21.8 mm | 9.2 mm | 11.1 mm | THT | ITE Industry Medical | CSA EAC EN IEC UL | EN 60950-1 IEC 60601-1 IEC 60950-1 UL 60950-1 | Remote Function | ||||||
1936 | Manufacturers Part No. REC5-2412SRW/H2/A(REC5-2412SRW/H2/A) Recom DC/DC converter regulated 12,00 V 0,420 A DIP24 2.000 V | Customer Part No. Customer Project No. | 29 Pcs. Planned Delivery Time Ø 17 Weeks | (at least 1 or mul. of 1) | Recom | 18.0 V | 36.0 V | 5.0 W | 1 | 12.0 V | 0.42 A | regulated | DIP24 | 2000.0 V | 85.0 % | -40.0 °C | 75.0 °C | 32.0 mm | 20.3 mm | 10.2 mm | THT | ITE Industry Medical | EN IEC UL | EN 60950-1 IEC 60601-1 UL 60950-1 | |||||||
1937 | Manufacturers Part No. REC5-2415DRWZ/H2/A(REC5-2415DRWZ/H2/A) Recom DC/DC converter regulated -15,00 V -0,170 A DIP24 2.000 V | Customer Part No. Customer Project No. | 59 Pcs. Planned Delivery Time Ø 17 Weeks | (at least 1 or mul. of 1) | Recom | 18.0 V | 36.0 V | 5.0 W | 2 | -15.0 V | -0.17 A | regulated | DIP24 | 2000.0 V | 85.0 % | -40.0 °C | 75.0 °C | 32.0 mm | 20.3 mm | 10.2 mm | THT | ITE Industry Medical | EN IEC UL | EN 60950-1 IEC 60601-1 UL 60950-1 | |||||||
1938 | Manufacturers Part No. REC5-243.3SRWZ/H2/A(REC5-243.3SRWZ/H2A) Recom DC/DC converter regulated 3,30 V 1,000 A DIP24 2.000 V | Customer Part No. Customer Project No. | 20 Pcs. Planned Delivery Time Ø 34 Weeks | (at least 1 or mul. of 1) | Recom | 18.0 V | 36.0 V | 5.0 W | 1 | 3.3 V | 1.0 A | regulated | DIP24 | 2000.0 V | 76.0 % | -40.0 °C | 75.0 °C | 32.0 mm | 20.3 mm | 10.2 mm | THT | ITE Industry Medical | EN IEC UL | EN 60950-1 IEC 60601-1 UL 60950-1 | |||||||
1939 | Manufacturers Part No. REC3-2412DRW/H4/A(REC3-2412DRW/H4/A) Recom DC/DC converter regulated -12,00 V -0,125 A DIP24 4.000 V | Customer Part No. Customer Project No. | 23 Pcs. Planned Delivery Time Ø 6 Weeks | (at least 1 or mul. of 1) | Recom | 18.0 V | 36.0 V | 3.0 W | 2 | -12.0 V | -0.125 A | regulated | DIP24 | 4000.0 V | 85.0 % | -40.0 °C | 85.0 °C | 32.0 mm | 20.3 mm | 10.2 mm | THT | ITE Industry Medical | EN IEC UL | EN 60601-1 EN 60950-1 IEC 60601-1 UL 60950-1 | |||||||
1940 | Manufacturers Part No. REC3-2412SRWZ/H2/A(REC3-2412SRWZ/H2/A) Recom DC/DC converter regulated 12,00 V 0,250 A DIP24 2.000 V | Customer Part No. Customer Project No. | 30 Pcs. Planned Delivery Time Ø 17 Weeks | (at least 1 or mul. of 1) | Recom | 9.0 V | 36.0 V | 3.0 W | 1 | 12.0 V | 0.25 A | regulated | DIP24 | 2000.0 V | 85.0 % | -40.0 °C | 85.0 °C | 32.0 mm | 20.3 mm | 10.2 mm | THT | ITE Industry Medical | EN IEC UL | EN 60950-1 IEC 60601-1 UL 60950-1 | |||||||
1941 | Manufacturers Part No. R24C2T25-R(R24C2T25-R) Recom DC/DC converter regulated -25 V -0,012 A SMD 3.000 V New | Customer Part No. Customer Project No. | 0 Pcs. Planned Delivery Time Ø 6 Weeks | (at least 750 or mul. of 750) | Recom | 21.0 V | 27.0 V | 2.0 W | 2 | -25.0 V | -0.012 A | regulated | SMD | 3000.0 V | 55.0 % | -40.0 °C | 125.0 °C | 7.5 mm | 3.55 mm | SMD | ITE Industry | DC-OK-Signal Remote Function Remote Sense | |||||||||
1942 | Manufacturers Part No. R24C2T25-CT(R24C2T25-CT) Recom DC/DC converter regulated -25 V -0,012 A SMD 3.000 V New | Customer Part No. Customer Project No. | 250 Pcs. Planned Delivery Time Ø 6 Weeks | (at least 1 or mul. of 1) | Recom | 21.0 V | 27.0 V | 2.0 W | 2 | -25.0 V | -0.012 A | regulated | SMD | 3000.0 V | 55.0 % | -40.0 °C | 125.0 °C | 7.5 mm | 3.55 mm | SMD | ITE Industry | DC-OK-Signal Remote Function Remote Sense | |||||||||
1943 | Manufacturers Part No. REC5K-2405SRW/H4/A(REC5K-2405SRW/H4/A) Recom DC/DC converter regulated 5 V 1 A DIP24 4.000 V New | Customer Part No. Customer Project No. | 63 Pcs. Planned Delivery Time Ø 12 Weeks | (at least 1 or mul. of 1) | Recom | 9.0 V | 36.0 V | 5.0 W | 1 | 5.0 V | 1.0 A | regulated | DIP24 | 4000.0 V | 78.0 % | -40.0 °C | 105.0 °C | 32.1 mm | 20.6 mm | 10.2 mm | THT | ITE Industry | CSA EN IEC UL | EN 62368-1 IEC 62368-1 UL 62368-1 | Remote Function | ||||||
1944 | Manufacturers Part No. RMD150-110-24SUW(RMD150-110-24SUW) Recom DC/DC converter regulated 24 V 6,25 A Enclosed 5.000 V New | Customer Part No. Customer Project No. | 0 Pcs. Planned Delivery Time Ø 18 Weeks | (at least 1 or mul. of 1) | Recom | 16.8 V | 137.5 V | 150.0 W | 1 | 24.0 V | 6.25 A | regulated | Enclosed | 5000.0 V | 94.0 % | -40.0 °C | 90.0 °C | 188.6 mm | 116.0 mm | 42.5 mm | Push-In Terminal | ITE Industry Railway | CE EN IEC UKCA | EN 45545-2 EN 50155 EN 62368-1 IEC 62368-1 | Adjustable Output Voltage DC-OK-Signal Parallel Function Peak Power Remote Function | ||||||
1945 | Manufacturers Part No. RMD300-110-24SUW(RMD300-110-24SUW) Recom DC/DC converter regulated 24 V 12,5 A Enclosed 5.000 V New | Customer Part No. Customer Project No. | 0 Pcs. Planned Delivery Time Ø 18 Weeks | (at least 1 or mul. of 1) | Recom | 16.8 V | 137.5 V | 300.0 W | 1 | 24.0 V | 12.5 A | regulated | Enclosed | 5000.0 V | 94.0 % | -40.0 °C | 90.0 °C | 209.0 mm | 141.0 mm | 48.0 mm | Push-In Terminal | ITE Industry Railway | CE EN IEC UKCA | EN 45545-2 EN 50155 EN 62368-1 IEC 62368-1 | Adjustable Output Voltage DC-OK-Signal Parallel Function Peak Power Remote Function | ||||||
1946 | Manufacturers Part No. R05C1TF05S-R(R05C1TF05S-R) Recom DC/DC converter regulated 5 V 0,2 A LGA 3.000 V New | Customer Part No. Customer Project No. | 0 Pcs. Planned Delivery Time Ø 6 Weeks | (at least 500 or mul. of 1) | Recom | 4.5 V | 5.5 V | 1.0 W | 1 | 5.0 V | 0.2 A | regulated | LGA | 3000.0 V | 50.5 % | -40.0 °C | 80.0 °C | 5.0 mm | 4.0 mm | 1.18 mm | SMD | ITE Industry | Adjustable Output Voltage Remote Function | ||||||||
1947 | Manufacturers Part No. R05C1TF05S-CT(R05C1TF05S-CT) Recom DC/DC converter regulated 5 V 0,2 A LGA 3.000 V New | Customer Part No. Customer Project No. | 139 Pcs. Planned Delivery Time Ø 25 Weeks | (at least 1 or mul. of 1) | Recom | 4.5 V | 5.5 V | 1.0 W | 1 | 5.0 V | 0.2 A | regulated | LGA | 3000.0 V | 50.5 % | -40.0 °C | 80.0 °C | 5.0 mm | 4.0 mm | 1.18 mm | SMD | ITE Industry | Adjustable Output Voltage Remote Function | ||||||||
1948 | Manufacturers Part No. MDS02L-03N(MDS02L-03N) MEAN WELL DC/DC converter unregulated 3,3 V 0,606 A SIP7 6.000 V New | Customer Part No. Customer Project No. | 24 Pcs. Planned Delivery Time Ø 22 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 4.5 V | 5.5 V | 2.0 W | 1 | 3.3 V | 0.606 A | unregulated | SIP7 | 6000.0 V | 77.0 % | -40.0 °C | 95.0 °C | 19.7 mm | 7.1 mm | 11.5 mm | THT | ITE Industry Medical | CE EAC IEC UKCA UL | IEC 60601-1 IEC 62368-1 UL 62368-1 | |||||||
1949 | Manufacturers Part No. MDS02L-05N(MDS02L-05N) MEAN WELL DC/DC converter unregulated 5 V 0,4 A SIP7 6.000 V New | Customer Part No. Customer Project No. | 0 Pcs. Planned Delivery Time Ø 22 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 4.5 V | 5.5 V | 2.0 W | 1 | 5.0 V | 0.4 A | unregulated | SIP7 | 6000.0 V | 80.0 % | -40.0 °C | 95.0 °C | 19.7 mm | 7.1 mm | 11.5 mm | THT | ITE Industry Medical | CE EAC IEC UKCA UL | IEC 60601-1 IEC 62368-1 UL 62368-1 | |||||||
1950 | Manufacturers Part No. MDS01M-15N(MDS01M-15N) MEAN WELL DC/DC converter unregulated 15 V 0,067 A SIP7 6.000 V New | Customer Part No. Customer Project No. | 3 Pcs. Planned Delivery Time Ø 22 Weeks | (at least 1 or mul. of 1) | MEAN WELL | 10.8 V | 13.2 V | 1.0 W | 1 | 15.0 V | 0.067 A | unregulated | SIP7 | 6000.0 V | 83.0 % | -40.0 °C | 95.0 °C | 19.7 mm | 7.1 mm | 11.5 mm | THT | Medical | CE EAC IEC UKCA | IEC 60601-1 |