DC/DC-Converters Isolated

(2077 Results)

Filters
Filter articles
Manufacturer
Manufacturer
Series
Series
Input voltage min. DC
Input voltage min. DC
Input voltage max. DC
Input voltage max. DC
Output Power
Output Power
Number of outputs
Number of outputs
Output voltage
Output voltage
Output current
Output current
Operating mode
Operating mode
Package/Case
Package/Case
Isolation voltage I/P-O/P
Isolation voltage I/P-O/P
Efficiency
Efficiency
Operating Temperature Min.
Operating Temperature Min.
Operating Temperature Max.
Operating Temperature Max.
Dimension: Length
Dimension: Length
Dimension: Width
Dimension: Width
Dimension: Height
Dimension: Height
Connection type, output
Connection type, output
Application
Application
Approvals
Approvals
Standards (safety)
Standards (safety)
Features
Features
Filter results
Results (2077)
Not discontinued
In stock
RoHS compliant
Datasheet
New
Show Selected
Image
Part No.
Indiv. Part No.
Manufacturer
Price
Availability
Quantity
Series
Data Sheet
RoHS
Manufacturer
Input voltage min. DC
Input voltage max. DC
Output Power
Number of outputs
Output voltage
Output current
Operating mode
Package/Case
Isolation voltage I/P-O/P
Efficiency
Operating Temperature Min.
Operating Temperature Max.
Dimension: Length
Dimension: Width
Dimension: Height
Connection type, output
Application
Approvals
Standards (safety)
Features
76
Manufacturers Part No.
(SKMW30F-12)
MEAN WELL DC/DC converter regulated 12 V 2,5 A 1"*1" 1.500 V
Customer Part No.
Customer Project No.
18 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
36.0 V
30.0 W
1
12.0 V
2.5 A
regulated
1"*1"
1500.0 V
89.0 %
-40.0 °C
85.0 °C
25.4 mm
25.4 mm
10.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
77
Manufacturers Part No.
(SKA20C-05)
MEAN WELL DC/DC converter regulated 5 V 0,4 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
30 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
36.0 V
75.0 V
20.0 W
1
5.0 V
0.4 A
regulated
2"*1"
1500.0 V
88.5 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
11.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
78
Manufacturers Part No.
(MDS15C-15)
MEAN WELL DC/DC converter regulated 15 V 1 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
5 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
36.0 V
75.0 V
15.0 W
1
15.0 V
1.0 A
regulated
2"*1"
4000.0 V
87.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
79
Manufacturers Part No.
(SKA20C-12)
MEAN WELL DC/DC converter regulated 12 V 1,666 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
12 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
36.0 V
75.0 V
20.0 W
1
12.0 V
1.666 A
regulated
2"*1"
1500.0 V
87.5 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
11.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
80
Manufacturers Part No.
(SKMW30F-15)
MEAN WELL DC/DC converter regulated 15 V 2 A 1"*1" 1.500 V
Customer Part No.
Customer Project No.
59 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
36.0 V
30.0 W
1
15.0 V
2.0 A
regulated
1"*1"
1500.0 V
89.0 %
-40.0 °C
85.0 °C
25.4 mm
25.4 mm
10.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
81
Manufacturers Part No.
(MDS15C-24)
MEAN WELL DC/DC converter regulated 24 V 0,625 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
10 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
36.0 V
75.0 V
15.0 W
1
24.0 V
0.625 A
regulated
2"*1"
4000.0 V
88.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
82
Manufacturers Part No.
(RSDW20F-03)
MEAN WELL DC/DC converter regulated 3,3 V 5,5 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
6 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
36.0 V
20.0 W
1
3.3 V
5.5 A
regulated
2"*1"
1500.0 V
87.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
83
Manufacturers Part No.
(SKMW30G-05)
MEAN WELL DC/DC converter regulated 5 V 6 A 1"*1" 1.500 V
Customer Part No.
Customer Project No.
62 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
30.0 W
1
5.0 V
6.0 A
regulated
1"*1"
1500.0 V
90.0 %
-40.0 °C
85.0 °C
25.4 mm
25.4 mm
10.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
84
Manufacturers Part No.
(MDS20A-05)
MEAN WELL DC/DC converter regulated 5 V 4 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
2 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
18.0 V
20.0 W
1
5.0 V
4.0 A
regulated
2"*1"
4000.0 V
86.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
85
Manufacturers Part No.
(SKMW30G-12)
MEAN WELL DC/DC converter regulated 12 V 2,5 A 1"*1" 1.500 V
Customer Part No.
Customer Project No.
149 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
30.0 W
1
12.0 V
2.5 A
regulated
1"*1"
1500.0 V
89.0 %
-40.0 °C
85.0 °C
25.4 mm
25.4 mm
10.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
86
Manufacturers Part No.
(RSDW20F-12)
MEAN WELL DC/DC converter regulated 12 V 1,67 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
20 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
36.0 V
20.0 W
1
12.0 V
1.67 A
regulated
2"*1"
1500.0 V
90.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
87
Manufacturers Part No.
(MDS20A-15)
MEAN WELL DC/DC converter regulated 15 V 1,333 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
5 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
18.0 V
20.0 W
1
15.0 V
1.333 A
regulated
2"*1"
4000.0 V
88.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
88
Manufacturers Part No.
(MDS20A-24)
MEAN WELL DC/DC converter regulated 24 V 0,833 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
11 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
18.0 V
20.0 W
1
24.0 V
0.833 A
regulated
2"*1"
4000.0 V
88.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
89
Manufacturers Part No.
(RSDW20G-03)
MEAN WELL DC/DC converter regulated 3,3 V 5,5 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
10 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
20.0 W
1
3.3 V
5.5 A
regulated
2"*1"
1500.0 V
88.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
90
Manufacturers Part No.
(MDS20B-05)
MEAN WELL DC/DC converter regulated 5 V 4 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
7 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
36.0 V
20.0 W
1
5.0 V
4.0 A
regulated
2"*1"
4000.0 V
86.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
91
Manufacturers Part No.
(RSDW20G-05)
MEAN WELL DC/DC converter regulated 5 V 4 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
22 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
20.0 W
1
5.0 V
4.0 A
regulated
2"*1"
1500.0 V
89.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
92
Manufacturers Part No.
(MDS20B-12)
MEAN WELL DC/DC converter regulated 12 V 1,67 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
0 Pcs.
Next Stock Receipt
Week 05/2025
(25 Pcs.)
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
36.0 V
20.0 W
1
12.0 V
1.67 A
regulated
2"*1"
4000.0 V
88.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
93
Manufacturers Part No.
(RSDW20G-12)
MEAN WELL DC/DC converter regulated 12 V 1,8 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
8 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
20.0 W
1
12.0 V
1.8 A
regulated
2"*1"
1500.0 V
90.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
94
Manufacturers Part No.
(MDS20B-15)
MEAN WELL DC/DC converter regulated 15 V 1,333 A 2"*1" 4.000 V
Customer Part No.
Customer Project No.
4 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
36.0 V
20.0 W
1
15.0 V
1.333 A
regulated
2"*1"
4000.0 V
89.0 %
-40.0 °C
90.0 °C
50.8 mm
25.4 mm
12.0 mm
THT
Medical
CE
EAC
UKCA
IEC 60601-1
95
Manufacturers Part No.
(RSDW20G-15)
MEAN WELL DC/DC converter regulated 15 V 1,5 A 2"*1" 1.500 V
Customer Part No.
Customer Project No.
10 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
75.0 V
20.0 W
1
15.0 V
1.5 A
regulated
2"*1"
1500.0 V
90.0 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
96
Manufacturers Part No.
(RSDW20H-05)
MEAN WELL DC/DC converter regulated 5 V 5,6 A 2"*1" 3.000 V
Customer Part No.
Customer Project No.
9 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
43.0 V
160.0 V
20.0 W
1
5.0 V
5.6 A
regulated
2"*1"
3000.0 V
88.5 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
97
Manufacturers Part No.
(RSDW20H-15)
MEAN WELL DC/DC converter regulated 15 V 1 A 2"*1" 3.000 V
Customer Part No.
Customer Project No.
7 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
43.0 V
160.0 V
20.0 W
1
15.0 V
1.0 A
regulated
2"*1"
3000.0 V
89.5 %
-40.0 °C
85.0 °C
50.8 mm
25.4 mm
10.2 mm
THT
ITE
Industry
Railway
CE
EAC
EN
UKCA
EN 50155
IEC 60571
Remote Function
98
Manufacturers Part No.
(SCW20A-05)
MEAN WELL DC/DC converter regulated 5 V 4 A DIP24 1.500 V
Customer Part No.
Customer Project No.
51 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
9.0 V
18.0 V
20.0 W
1
5.0 V
4.0 A
regulated
DIP24
1500.0 V
86.0 %
-40.0 °C
80.0 °C
31.8 mm
20.3 mm
12.2 mm
THT
ITE
Industry
CE
EAC
UKCA
Remote Function
99
Manufacturers Part No.
(SKA40B-12)
MEAN WELL DC/DC converter regulated 12 V 3,33 A 2"*2" 1.500 V
Customer Part No.
Customer Project No.
48 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
18.0 V
36.0 V
40.0 W
1
12.0 V
3.33 A
regulated
2"*2"
1500.0 V
90.0 %
-40.0 °C
80.0 °C
50.8 mm
50.8 mm
11.0 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
Remote Sense
100
Manufacturers Part No.
(SKA40C-05)
MEAN WELL DC/DC converter regulated 5 V 7 A 2"*2" 1.500 V
Customer Part No.
Customer Project No.
12 Pcs.
Planned Delivery Time
Ø 22 Weeks
(at least 1 or mul. of 1)
MEAN WELL
36.0 V
75.0 V
35.0 W
1
5.0 V
7.0 A
regulated
2"*2"
1500.0 V
91.0 %
-40.0 °C
80.0 °C
50.8 mm
50.8 mm
11.0 mm
THT
ITE
Industry
CE
EAC
UKCA
Adjustable Output Voltage
Remote Function
Remote Sense