47132
Myrra AC/DC industrial power supply unit Enclosed Plastic 2,5W 5V 0,5A
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
18 Pcs. in stock
Planned delivery time
Ø 21 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between:
• Active (green)
• NRND = Not Recommended for New Designs (yellow)
• LTB = Last Time Buy (yellow)
• EOL = End of Life (red)
Active
Available (from stock)
Data Sheet
Prices
Manufacturer bundle 25 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.
Quantity and Options
(at least 1 or multiple of 1)
All prices net plus VAT. We do not deliver to private customers.
Fact Sheet
- Package/Case
- Enclosed Plastic
- Output Power
- 2.5 W
- Output voltage
- 5 V
- Output current
- 0.500 A
- Efficiency
- 65 %
- RoHS-Conform
Specifications
Open all
Operating conditions
- MTBF
- 550,000 h
- Operating Temperature Min.
- -25 °C
- Operating Temperature Max.
- 70 °C
- Storage Temperature Min.
- -10 °C
- Storage Temperature Max.
- 35 °C
Input
- Mains connection/phases
- I
- Mains frequency min.
- 47 Hz
- Mains frequency max.
- 63 Hz
- Input voltage min. AC
- 85 V
- Input voltage max. AC
- 265 V
- Input voltage min. DC
- 120 V
- Input voltage max. DC
- 370 V
- Input current
- 0.2 A
- Efficiency
- 65 %
- No load power, less than
- 0.3 W
- Power factor correction (PFC)
- Connection type, input
- THT
Output
- Number of outputs
- 1
- Output Power
- 2.5 W
- Output voltage
- 5 V
- Output voltage tolerance
- -5 %
- Ripple & Noise
- 200 mVp-p
- Output current
- 0.500 A
- Overload protection
- Short-circuit protection
- Overvoltage protection
- Overtemperature protection
- Connection type, output
- THT
Safety/Certifications
- Protection class
- II
- Isolation voltage I/P-O/P
- 4,000 V
- Approvals
- CE
- EN
- ENEC
- UL
- Standards (EMC)
- EN 55014
- EN 55032 Class B
- Standards (safety)
- EN 60335-1
- EN 60950-1
- EN 61558-1
- EN 61558-2-16
- EN 62368-1
- IEC 60950-1
- IEC 62368-1
- UL 60950-1