Image similar
Manufacturer Part No.
PWM-200-12BLE
Schukat Part No.
PWM-200-12BLE
Manufacturer
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.

42 Pcs. in stock

Planned delivery time
Ø 16 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between: • Active (green) • NRND = Not Recommended for New Designs (yellow) • LTB = Last Time Buy (yellow) • EOL = End of Life (red)
Active
Available (from stock)
Replacement / Follow-up View entire series
Data Sheet
ECAD Model
Downloads

Prices

Manufacturer bundle 12 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.

Quantity and Options

(at least 1 or multiple of 1)
All prices net plus VAT. We do not deliver to private customers.

Fact Sheet

Operating mode
CV
Output Power
180 W
Output voltage
12 V
Output current
15.000 A
Protection Class IP
IP67
Interfaces
Casambi
RoHS-Conform

Specifications

Open all

General

Manufacturer
  • MEAN WELL
Series
  • PWM-200IoT
Product group
  • L4739
Application
  • Lighting
Operating mode
  • CV
Package/Case
  • Enclosed Plastic
Dimension: Length
  • 195 mm
Dimension: Width
  • 68 mm
Dimension: Height
  • 39.5 mm
Weight
  • 1,030 g
Label
  • MM-Zeichen; SELV
Dimmable
Interfaces
  • Casambi
Manufacturer's warranty (years)
  • 5
Features
  • DC compatible
  • Emergency Lighting Unit
  • Independent Control Gear
Notice
  • Power supply for the operation of LED light sources. These products are not designed for operation in no-load condition. Waste electronic equipment is recyclable material and does not belong in household waste. If the device is at the end of its service life, dispose of it at the collection points of the disposal system in accordance with the applicable legal regulations. Disposal with household waste is prohibited.

Operating conditions

MTBF
  • 211,100 h
Operating expectation
  • 50,000 h
Operating Temperature Min.
  • -20 °C
Operating Temperature Max.
  • 85 °C
Storage Temperature Min.
  • -20 °C
Storage Temperature Max.
  • 80 °C

Input

Mains frequency min.
  • 47 Hz
Mains frequency max.
  • 63 Hz
Input voltage min. AC
  • 100 V
Input voltage max. AC
  • 305 V
Input voltage min. DC
  • 142 V
Input voltage max. DC
  • 431 V
Input current
  • 1.1 A
Efficiency
  • 92 %
No load power, less than
  • 0.5 W
Power consumption in networked standby mode (Pnet), less than
  • 0.5 W
Leakage current, max.
  • 0.75 mA
Inrush current, max.
  • 65 A
Max. number on B16 circuit breaker
  • 3
Max. number on C16 circuit breaker
  • 6
Power factor correction (PFC)
Power factor
  • 0.96
Connection type, input
  • Strand
Cable length, input
  • 30 cm

Output

Number of outputs
  • 1
Output Power
  • 180 W
Output voltage
  • 12 V
Output current
  • 15.000 A
Overload protection
Type of overload protection
  • Hiccup
Short-circuit protection
Overvoltage protection
Overtemperature protection
Connection type, output
  • Strand
Cable length, output
  • 30 cm

Safety/Certifications

Protection class
  • II
Protection Class IP
  • IP67
Isolation voltage I/P-O/P
  • 3,750 V
Approvals
  • BIS
  • CCC
  • CE
  • CSA
  • EAC
  • EN
  • ENEC
  • UKCA
  • UL
Standards (EMC)
  • EN 55015
Standards (safety)
  • EN 61347-1
  • EN 61347-2-13
  • UL 8750

Documents

MW_Catalog-led.pdf
MW_Industrial-EN-s.pdf