HLG-60H-42AB
MEAN WELL AC/DC LED power supply unit CV/CC 60,9W 42V 1,450A IP65 1-10 Volt PWM Resistiv
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
0 Pcs. in stock
Back Order
1 Pcs.
1 Pcs.
Planned delivery time
Ø 16 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between:
• Active (green)
• NRND = Not Recommended for New Designs (yellow)
• LTB = Last Time Buy (yellow)
• EOL = End of Life (red)
Active
Available on order
Data Sheet
Prices
Manufacturer bundle 20 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.
Quantity and Options
(at least 1 or multiple of 1)
All prices net plus VAT. We do not deliver to private customers.
Fact Sheet
- Operating mode
- CV/CC
- Output Power
- 60.9 W
- Output voltage
- 42 V
- Output current
- 1.450 A
- Protection Class IP
- IP65
- Interfaces
- 1-10 Volt
PWM
Resistiv - RoHS-Conform
Specifications
Open all
Operating conditions
- MTBF
- 338,000 h
- Operating expectation
- 62,000 h
- Operating Temperature Min.
- -40 °C
- Operating Temperature Max.
- 80 °C
- Storage Temperature Min.
- -40 °C
- Storage Temperature Max.
- 80 °C
Input
- Mains frequency min.
- 47 Hz
- Mains frequency max.
- 63 Hz
- Input voltage min. AC
- 90 V
- Input voltage max. AC
- 305 V
- Input voltage min. DC
- 127 V
- Input voltage max. DC
- 431 V
- Input current
- 0.32 A
- Efficiency
- 90 %
- Power consumption in standby mode (PSB), less than
- 0.5 W
- Leakage current, max.
- 0.75 mA
- Inrush current, max.
- 55 A
- Max. number on B16 circuit breaker
- 9
- Max. number on C16 circuit breaker
- 16
- Power factor correction (PFC)
- Power factor
- 0.95
- Connection type, input
- Strand
- Cable length, input
- 30 cm
Output
- Number of outputs
- 1
- Output Power
- 60.9 W
- Output voltage
- 42 V
- Output voltage tolerance
- -1 %
- Ripple & Noise
- 300 mVp-p
- Selectable output current
- Output current
- 1.450 A
- Overload protection
- Type of overload protection
- Constant Current Limitting
- Short-circuit protection
- Overvoltage protection
- Overtemperature protection
- Connection type, output
- Strand
- Cable length, output
- 30 cm
Safety/Certifications
- Protection class
- I
- Protection Class IP
- IP65
- Isolation voltage I/P-O/P
- 3,750 V
- Isolation voltage I/P-FG
- 2,000 V
- Isolation voltage O/P-FG
- 1,500 V
- Approvals
- AS/NZ
- CCC
- CE
- CSA
- EAC
- EN
- IEC
- KC
- UKCA
- UL
- Standards (EMC)
- EN 55015
- Standards (safety)
- EN 61347-1
- EN 61347-2-13
- IEC 61347-1
- IEC 61347-2-13
- UL 8750
Documents
LED_GE.pdf
MW_Catalog-led.pdf
MW_Industrial-EN-s.pdf