60.13.8.230.0040
Finder Industrial relay 60.13 3PDT 10A 230VAC 7.250Ohm
Enter your company's part number here. Your part number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
Enter your personal project number here to assign the item to a project. Your part project number will be referenced on your receipts, such as the order confirmation, invoice or delivery note.
15 Pcs. in stock
Next Stock Receipt
Week 49/2024
10 Pcs.
10 Pcs.
Planned delivery time
Ø 14 Weeks
Life Cycle Status
The life cycle indicates which market phase the item is in. We distinguish between:
• Active (green)
• NRND = Not Recommended for New Designs (yellow)
• LTB = Last Time Buy (yellow)
• EOL = End of Life (red)
Active
Available (from stock)
Data Sheet
Prices
Manufacturer bundle 10 Pcs.
Manufacturer's packaging unit (Mfr. PU) means the smallest original packaging unit of the manufacturer.
Price per 1 Pcs.
Quantity and Options
(at least 5 or multiple of 5)
All prices net plus VAT. We do not deliver to private customers.
Fact Sheet
- Type
- Industrial relay
- Series
- 60.13
- Rated voltage AC
- 230 V AC
- Rated current
- 10,5 mA
- Switching current
- 10 A
- contacts
- 3PDT
- Coil resistance
- 7,250 Ohm
- Dimension: Length
- 36.4 mm
- Dimension: Width
- 32.5 mm
- Dimension: Height
- 54.2 mm
- RoHS-Conform
Specifications
Open all
Dimensions and weights
- Dimension: Length
- 36.4 mm
- Dimension: Width
- 32.5 mm
- Dimension: Height
- 54.2 mm
Operating conditions
- Operating Temperature Min.
- -40 °C
- Operating Temperature Max.
- 70 °C
Technical features
- Rated voltage AC
- 230 V AC
- Coil design
- Switching voltage, max. AC
- 400 V AC
- Response voltage
- 108 V
- Operating voltage, max.
- 253 V
- Test voltage open contacts
- 1,000 V AC
- Test voltage coil/contact
- 3,600 V AC
- Rated current
- 10,5 mA
- Switching current
- 10 A
- Continuous current
- 10 A
- Inrush current
- 20 A
- Rated power
- 500 mW
- Switching capacity (VA)
- 500 VA
- Coil resistance
- 7,250 Ohm
- Response time
- 11 ms
- Drop-out time
- 4 ms
- Vibration resistance
- NO/NC: 22 G / 22 G
- Impact resistance, functional
- 20 G
Safety/Certifications
- Approvals
- CCC
- CE
- RINA
- VDE
- cCSA
- cULus
- Protection class RT
- RTI